Technical Data

Electrical data

Nominal input voltage

220…240 V

Mains frequency

50 60 Hz

Input voltage AC

198…264 V


Total harmonic distortion

< 20 %

Power factor λ

0.95 0.90


ECG efficiency

79 %


Device power loss

2.8 W


Inrush current

5 A


Max. ECG no. on circuit breaker 10 A (B)

101

Max. ECG no. on circuit breaker 16 A (B)

160

Max. ECG no. on circuit breaker 25 A (B)

Surge capability (L N-Ground)

1 kV

Surge capability (L-N)

1 kV

Nominal output voltage

7…14 V

U-OUT (working voltage)

25 V

Nominal output current

700 mA


Output current tolerance

±10 %

Output ripple current (100 Hz)

35 %


Output PSTLM

≤1

Output SVM

≤1.0

Nominal output power

10 W


Galvanic isolation

SELV

Dimensions & weight

Mounting hole spacing, length

Mounting hole spacing, width

Product weight

81.00 g

Cable cross-section, input side

0.75…1.5 mm²


Cable cross-section, output side

0.5…1.5 mm²


Wire preparation length, input side

8.0…9.0 mm

Wire preparation length, output side

8.0…9.0 mm

Height

25.0 mm

Length

95.0 mm

Width

53.0 mm

Colors & materials

Casing material

Plastic

Temperatures & operating conditions

Ambient temperature range

-20…+55 °C

Maximum temperature at tc test point

80 °C


Max.housing temperature in case of fault

110 °C

Temperature range at storage

-25…75 °C

Permitted rel. humidity during operation

5…85 %


Lifespan

ECG lifetime

50000 h


Capabilities

Dimmable

Yes

Dimming interface

Phase Cut


Dimming range

10…100 %

Dimming method

Amplitude Modulation

Overheating protection

Automatic reversible

Overload protection

Automatic reversible

Short-circuit protection

Automatic reversible

No-load proof

Yes

Max. cable length to lamp LED module

2.0 m

Suitable for fixtures with prot. class

I II

Type of connection, output side

Push terminal

Certificates & standards

Approval marks – approval

CE ENEC 10 VDE CB

Standards

Acc. to IEC 61347-1 Acc. to IEC 61347-2-13 Acc. to IEC 62384 Acc. to CISPR 15 Acc. to IEC 61000-3-2 Acc. to IEC 61000-3-3 Acc. to IEC 61547